@article{e0f7cc725e4b4516b088922eccf02733,
title = "Hemodynamically significant atrial septal defect after atrial fibrillation ablation: A hole to remember",
author = "Yousuf, \{Mian Atif\} and Sulsal Haq and O{\textquoteright}Donnell, \{Robert E.\} and Mehran Attari",
note = "A 67-year-old woman was referred for cryoablation after flecainide therapy for symptomatic paroxysmal atrial fibrillation (PAF) was unsuccessful. A transesophageal echocardiogram performed immediately before the ablation was unremarkable. Double-transseptal puncture with a Brockenbrough needle through 8F SL0 and SL2 sheaths was performed.",
year = "2015",
month = sep,
day = "1",
doi = "10.1016/J.HRTHM.2015.04.036",
language = "American English",
volume = "12",
journal = "Heart Rhythm",
issn = "1556-3871",
publisher = "Elsevier",
number = "9",
}