@article{fb44504c3eb746b098898eb9754ded2f,
title = "Implantation of leadless pacemakers via inferior vena cava filters is feasible and safe: Insights from a multicenter experience.",
author = "Mahmoud Houmsse and Roshan Karki and James Gabriels and Michael Reinig and Dilesh Patel and Hussain, \{Sarah K.\} and Gandhi, \{Gaurang D.\} and Lloyd, \{Michael S.\} and Makary, \{Mina S.\} and Toshimasa Okabe and Kamala Tamirisa and Jacqueline Joza and Apoor Patel and Afzal, \{Muhammad R.\} and Epstein, \{Laurence M.\} and Cha, \{Yong Mei\}",
note = "{\textcopyright} 2020 Wiley Periodicals LLC Background: The leadless Micra transcatheter-pacing system (Micra-TPS) is implanted via a femoral approach using a 27-French introducer sheath. The Micra Transcutaneous Pacing Study excluded patients with inferior vena cava (IVC) filters. Objective: To examine the feasibility and safety of Micra-TPS implantation through an IVC filter.",
year = "2020",
month = dec,
day = "1",
doi = "10.1111/JCE.14776",
language = "American English",
volume = "31",
journal = "Journal of Cardiovascular Electrophysiology",
number = "12",
}