title = "Low tidal volume and high positive end-expiratory pressure mechanical ventilation results in increased inflammation and ventilator-associated lung injury in normal lungs.",
author = "Hong, \{Caron M.\} and Qi Lu and Yunhui Cheng and Vadim Pisarenko and Danielle Doucet and Margaret Brown and Seena Aisner and Chunxiang Zhang and Deitch, \{Edwin A.\} and Ellise Delphin",
note = "BACKGROUND: Protective mechanical ventilation with low tidal volume (VT) and low plateau pressure reduces mortality and decreases the length of mechanical ventilation in patients with acute respiratory distress syndrome. Mechanical ventilation that will protect normal lungs during major surgical procedures of long duration may improve postoperative outcomes.",