@article{792fe9028cc747508dfc8ff21094716f,
title = "Use of Genetic Testing for Targeted Anticoagulation in Patients on Long-Term Mechanical Circulatory Support",
author = "T.M. Dewey and M.A. Herbert and C.M. Worley and D.S. Savor and E.J. Eichhorn and B.S. Bowers and M.J. Magee",
note = "Non-pulsatile axial flow circulatory support (CS) devices require anticoagulation with Warfarin and either single or duel antiplatelet agents to prevent pump thrombosis. Pharmacologic responsiveness to these agents may have significant implications in regards to device management and risk of complications.",
year = "2013",
month = apr,
day = "1",
doi = "10.1016/J.HEALUN.2013.01.009",
language = "American English",
volume = "32",
journal = "Journal of Heart and Lung Transplantation",
number = "4",
}